How can clinically-safe and effective Platelet Rich Plasma
Main Article Content
Abstract
Aim: To compare open and closed systems in the preparation of Platelet Rich Plasma (PRP) in terms of feasibility, cost, and safety. Materials and Methods: In this prospective study 10 patients who were undergoing controlled ovarian hyperstimulation and intrauterine insemination, were included. Open system PRP prepeared from these patients collected blood which have the highest number of platelets. Open system PRP’s platelet concentration and cost were compared with closed system kit. Results: It was found that 778g (2000rpm) was the best centrifugal force, and 5 minutes was the optimum duration for having the highest level of platelets. The mean platelet concentrations in the open system (425 ± 91.2 × 103/ml) were statistically significantly higher than the closed system (298 ± 88.32 × 103/ml) (p = 0.021). No growth was observed in the culture inoculated with PRPs obtained using open system. In the cost analysis, the open system was significantly more economic than the closed system. Conclusions: Higher platelet concentrations can be achieved using a low-cost sterile open system centrifugation method than the closed system kit in the laboratory setting effectively.
Downloads
Download data is not yet available.
Article Details
How to Cite
Atasoy Karakas, L., Deniz Ercan, D., Karabay, E., Gumuslu, S., & Onur Karabacak, R. (2021). How can clinically-safe and effective Platelet Rich Plasma . Annals of Medical Research, 27(11), 2933–2939. Retrieved from http://annalsmedres.org/index.php/aomr/article/view/1049
Section
Original Articles
CC Attribution-NonCommercial-NoDerivatives 4.0